Back To Top

Spartan’s TUS FB107TL system accurately monitors off loading from a truck bay for hydrocarbon fluids such as condensate or light to heavy density crude oil.

The system utilizes Rosemount’s Micro Motion Coriolis meter for volume flow measurement and water cut determination. The meter provides three on-line measurements that include mass flow, density and temperature.

Volume measurement is derived from the mass and density variables and the meter can be used over a wide range of density and volume flow rates providing custody transfer accuracy. The TUS FB107 system incorporates patented Density Compensation for 0-5% monitoring and a patented Net Oil Density Comparison for the 5-100% water cut calculation.

Features

  • AER Directive 17
  • API Chapter 11.1 2004 calculations
  • Supports 1 truck unloading bay
  • Based on FloBoss 107 Flow Manager
  • Local operator interface
  • Keypad or PC configuration
  • 0-100% water cut measurement calculation
  • Liquid volume correction for crude oil